Abstract
An apparatus for measuring coal slurry at coal liquefaction condition were made. A calculation method, power number method, which suits for this apparatus were developed. The measuring range is: Re<300, during this range, the method works well. Glycerin was taken as a standard reagent to check the reliability of the apparatus and the power number method. The results of viscosity data of a Chinese brown coal slurry were presented using the apparatus and the power number method. The viscositytemperature curve was obtained. It was found that the curve is suitable for Vogel equation at 300℃.
-
-