Graphical Abstract
-
Abstract
The sampler for PM10 from atmosphere was refit, with which a set of PM10 (inhaled particulate matter) sampling system applied in flue gas from waste incinerators was established. With the sampling system PM10 from 3 different incinerators was sampled respectively. 16 kinds of polycyclic aromatic hydrocarbons (PAHs) in PM10 were quantified by GC-MS. The mass fraction of PAHs in PM10 and the concentration of PAHs in flue were obtained. The PAHs with different rings were compared. And the toxic parameters of PAHs were analyzed. The result show that most of the PAHs in PM10 is of 4, 5, and 6 rings, while only little PAHs is of 3 and 2 rings. Compared with coalfired power plant, the concentration and toxic parameters of PAHs emitted from waste incinerators are higher.
-
-